DURKOPP ADLER 827-M Operating Manual page 100

Hide thumbs Also See for 827-M:
Table of Contents

Advertisement

98
Code
Possible cause
3100
AC-RDY timeout,
intermediate circuit voltage
did not reach the defined
threshold in the specified
time
3101
High voltage fault, mains
voltage, longer duration
>290 V
3102
Low voltage failure
nd
(2
threshold)
(mains voltage < 150 V AC)
3105
U24 V short circuit
3106
2
U24 V (I
T) overload
3107
Pedal not connected
6353
Internal EEprom
communication error
6354
External EEprom
communication error
8401
Watchdog
Remedial action
• Check the mains voltage
If the mains voltage is OK,
replace the control
• Check the mains voltage
If nominal voltage is
continuously exceeded,
stabilize it or use a generator
• Check the mains voltage
• Stabilize the mains voltage
• Use generator
• Disconnect 37-pin plug
If the error is not corrected:
Replace the control
• Test inputs and outputs for
24 V short circuit
• One or several magnets
defective
• Connect the pedal
• Switch off the control, wait until
the LEDs are off and then
switch on again
• Switch off the control, wait until
the LEDs are off, check
connection for machine ID, and
switch on control again
• Perform software update
• Perform a machine ID reset
• Replace the control
Operating Instructions 827/827-M - 01.0 - 02/2019
Troubleshooting