134
FEP630, FEH630 ELECTROMAGNETIC FLOWMETER | OI/FEP630/FEH630-EN REV. D
... 13 Specification
... ProcessMaster – Temperature data
Remote mount design
Flowmeter sensor in standard version
Lining material
Flange material
Hard rubber
Steel
Hard rubber
Stainless steel
Soft rubber
Steel
Soft rubber
Stainless steel
PTFE
Steel
PTFE
Stainless steel
Thick PTFE***
Steel
Thick PTFE***
Stainless steel
PFA***
Steel
PFA***
Stainless steel
ETFE***
Steel
ETFE***
Stainless steel
Linatex*
Steel
Linatex*
Stainless steel
Ceramic carbide
Steel
Ceramic carbide
Stainless steel
*
Only for China production site
** For (optional) low-temperature version only
*** Only for design level 'A'
Ambient temperature range (
Minimum
-10 °C (14 °F)
60 °C (140 °F)
-15 °C (5 °F)
60 °C (140 °F)
-10 °C (14 °F)
60 °C (140 °F)
-15 °C (5 °F)
60 °C (140 °F)
-10 °C (14 °F)
60 °C (140 °F)
-25 °C (-13 °F)
60 °C (140 °F)
−40 °C (−40 °F)**
-10 °C (14 °F)
60 °C (140 °F)
-25 °C (-13 °F)
60 °C (140 °F)
−40 °C (-40 °F)**
-10 °C (14 °F)
60 °C (140 °F)
-25 °C (-13 °F)
60 °C (140 °F)
−40 °C (-40 °F)**
-10 °C (14 °F)
60 °C (140 °F)
-25 °C (-13 °F)
60 °C (140 °F)
-10 °C (14 °F)
60 °C (140 °F)
-20 °C (-4 °F)
60 °C (140 °F)
-10 °C (14 °F)
60 °C (140 °F)
-25 °C (-13 °F)
60 °C (140 °F)
)
Measuring medium temperature (T
Tamb
Maximum
Minimum
-10 °C (14 °F)
−5 °C (23 °F)*
-15 °C (5 °F)
−5 °C (23 °F)*
-10 °C (14 °F)
-15 °C (5 °F)
-10 °C (14 °F)
-25 °C (-13 °F)
-10 °C (14 °F)
-25 °C (-13 °F)
-10 °C (14 °F)
-25 °C (-13 °F)
-10 °C (14 °F)
-25 °C (-13 °F)
-10 °C (14 °F)
-20 °C (-4 °F)
-10 °C (14 °F)
-20 °C (-4 °F)
)
medium
Maximum
85 °C (185 °F)
80 °C (176 °F)*
85 °C (185 °F)
80 °C (176 °F) *
60 °C (140 °F)
60 °C (140 °F)
130 °C (266 °F)
130 °C (266 °F)
130 °C (266 °F)
130 °C (266 °F)
130 °C (266 °F)
130 °C (266 °F)
130 °C (266 °F)
130 °C (266 °F)
70 °C (158 °F)
70 °C (158 °F)
80 °C (176 °F)
80 °C (176 °F)