Operating instruction
d
42/14 41 EN
Thermal Mass Flowmeter FMT200-ECO2
(Sensyflow eco2)
for air, compact configuration

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FMT200-ECO2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ABB FMT200-ECO2

  • Page 1 Operating instruction 42/14 41 EN Thermal Mass Flowmeter FMT200-ECO2 (Sensyflow eco2) for air, compact configuration...
  • Page 2 Tel: +49 6023 - 0 Fax: +49 6023 - 3210 © Copyright 2003 by ABB Automation Products GmbH We reserve the right to technical amendments This document is protected by copyright. Information in this document is intended only to assist the user in safe and efficient operation of the equipment.
  • Page 3: Table Of Contents

    ............24 42/14-41 EN Thermal Mass Flowmeter FMT200-ECO2...
  • Page 4 ..........27 Thermal Mass Flowmeter FMT200-ECO2...
  • Page 5: Important Information In Advance

    Important information in advance Congratulations! By purchasing this Mass Flow Meter FMT200-ECO2 (Sensyflow eco2), you have acquired a device which satisfies the highest quality and performance standards. FMT200-ECO2 (Sensyflow eco2) is the result of our long experience; it has been conceived in direct response to customer requirements.The modular set- up and the many adaptation possibilities guarantee utmost ease of operation and great versatility.Our cal-...
  • Page 6: Application According To Designation, General Safety Instructions

    The examination intervals must be chosen in such a way that any damages that can be expected can be recognised in time. The examinations must be performed at least every three years. The examinations can be skipped if the electrical system is continuously monitored by a responsible en- gineer. Thermal Mass Flowmeter FMT200-ECO2 42/14-41 EN...
  • Page 7: Notes Regarding Operation In Hazardous Areas

    EC declaration of conformity (ATEX) . For the operation of Zone2 / Zone 22 certified devices only the values written down in this declaration of conformity (ATEX) are relevant. Warning Operating the device in Zone 1/ 21 or Zone 0 / 20 is not permitted. STOP 42/14-41 EN Thermal Mass Flowmeter FMT200-ECO2...
  • Page 8: Description

    Description 3 Description 3.1 Process connectors The process connectors provided for FMT200-ECO2 (Sensyflow eco2) ensure user-specific utilization without extra mounting costs. Furthermore, they enable easy installation and removal of the measurement sensor for maintenance and cleaning purposes. 3.2 Measuring sensor Apart from the sensor unit, the measuring sensor, which is set up as a pipe, also contains the transformer electronics.
  • Page 9: Installation And Start-Up

    • Components affecting flow, such as valves or shut-off fittings should be possibly installed behind the measuring point. Should there be any uncertainty or questions regarding the measuring point to be selected, please con- tact the ABB Service Team in Alzenau. Tel: +49 6023/92-3267 or +49 6023/92-3597...
  • Page 10: Installing The Process Adapter Into The Measuring Pipe

    Connection to the small flange adapter 4.4.2 G1“, G3/4“ threaded joints 4.4.3 G1/2“, G3/8“ threaded joints Both adapters are equipped with a High-Tec flow conditioner sieve on the inflow side. Because of it, no steadying lengths are required. Thermal Mass Flowmeter FMT200-ECO2 42/14-41 EN...
  • Page 11: Legris Hose Adapters

    Installation and start-up 4.4.4 Legris hose adapters The hose adapters are screwed into the G3/8" process adapters. 4.4.5 Transair adapters The Transair adapters are screwed into the G 3/4" adapters. 42/14-41 EN Thermal Mass Flowmeter FMT200-ECO2...
  • Page 12: Electrical Connections

    Upon selection, the analog output of the current output supplies an active signal of 0(4)...20 mA, i.e. the FMT200-ECO2 (Sensyflow eco2) device supplies the current independently. For this reason, do not use a 2-wire power supply unit or an active input of a PLC, but rather a passive signal receiver.
  • Page 13: Active Digital Output Wiring

    Sensyflow eco1 and FMT200-ECO2 (Sensyflow eco2) are compatible. Using the appropriate electrical adapter, FMT200-ECO2 can be connected to existing plants. As "interface" and "digital output" function- ality is not available with Sensyflow eco1, there is no wiring within the adapter for these functions.
  • Page 14: Changing The Configuration

    Fig. 6-2 Verzeichnis = Directory Click on the button „Verzeichnis wechseln“ to change the installation directory Setup beenden (Exit Setup) Click here to exit the installation Click on the computer symbol to continue the installation. Thermal Mass Flowmeter FMT200-ECO2 42/14-41 EN...
  • Page 15: Starting The Configuration Program

    In this case, check if you have selected the correct interface, Are all cables connected ? Is the FMT200-ECO2 (Sensyflow eco2) in operation (green light)? Fig. 6-6 If the connection is successfully established, you will see the first page of the configuration program.
  • Page 16: The Page „Actual Settings

    6.3.3 Standard specification If the FMT200-ECO2 (Sensyflow eco2) is operating with a standard volume flow measuring unit, you can see the standard state conditions in this window. If the device is running with a mass flow unit, this win- dows stays empty.
  • Page 17: Actual Settings: Digital Output

    Which electrical analog output is active? Analog output: Fig. 6-12 actual measuring value as analog signal (mA or V). Output at error: FMT200-ECO2 signalizes an error at the analog output. Filter factor: time constant of the damping. Offset suppression: Measuring values smaller than the adjusted one will be shown as zero flow.
  • Page 18: Measured Value

    The control LED still shows permanent red after the procedure. Now, by short interruption of the supply voltage a hardware-reset will be performed. After this, the control LED turns to permanent green and the device works properly. Thermal Mass Flowmeter FMT200-ECO2 42/14-41 EN...
  • Page 19: Password

    With the standard density of air = 1,293 kg/Nm³ one air-balloon is filled with 0,00905 kg. That means 1 kg/h is approx. 110 air-balloons/h, or 1,84 air-balloons/min. The standard density is related to 0°C, 1013 mbar. With „delete unit“ at the configuration menu, you can delete the new unit. 42/14-41 EN Thermal Mass Flowmeter FMT200-ECO2...
  • Page 20: Analog Output Parameter Settings

    This page allows parameter settings of the analog output. For a better overview, the actual and the new parameters are both shown. The new settings will be sent to the FMT200-ECO2 (Sensyflow eco2) when the save-command is select- ed from the „save data“ menu.
  • Page 21: Digital Output Parameter Settings

    The new settings will be sent to the device when the „save“-command is selected from the „save data“ menu. After saving the data the FMT200-ECO2 (Sensyflow eco2) will initialize itself. During the save-initializa- tion phase, the LED is blinking red.
  • Page 22: Switch Output

    Changing the configuration 6.5.4 Switch output In this mode the FMT200-ECO2 (Sensyflow eco2) will observe whether the actual measuring value is be- tween the adjusted limits. The polarity informs the eco2, how the signal should react. Fig. 6-20 6.5.5 No output This mode disables the digital output.
  • Page 23: Maintenance

    Under no circumstances, components such as the honeycomb or sieve may be removed from the probe, bent or damaged in any way. Non-compliance with the cleaning steps described above may lead to damage of the probe. 42/14-41 EN Thermal Mass Flowmeter FMT200-ECO2...
  • Page 24: Technical Data

    2) It is possible to specify any unit which you can transform into a mass or stan- dard volume flow. For Example 1 ballon/min = 7 l/min - q Thermal Mass Flowmeter FMT200-ECO2 42/14-41 EN...
  • Page 25: Packaging For Transport

    COMx port of your PC or Laptop to the service and configuration box. Using the configuration software, all measur- ing ranges and output signals can be adjusted to your needs. FMT200-ECO2 RS 232 42/14-41 EN Thermal Mass Flowmeter FMT200-ECO2...
  • Page 26: Technical Information And Measuring Principle

    These corrective measures make measurements more expensive and they reduce the ultimate accuracy of the measuring system. FMT200-ECO2 (Sensyflow eco2) measuring systems provide the mass flow rate di- rectly, i.e. without further measurement or correction.
  • Page 27: Ec-Declaration Of Conformity

    Emission: EN 50 081-1:1992 Immunity: EN 50 082-2:1995 EN 61326-1:1997 Basic standards: EN 61000-4 part 2,3,4,5,6 and 11 ABB Automation Products GmbH Alzenau, Januar 2001 investigationreport: 001-11/98 conformitätsnr.: F01-11-98 42/14-41 EN Thermal Mass Flowmeter FMT200-ECO2...
  • Page 31 Appendix: Statement of contamination Appendix: Statement of contamination Statement about the contamination of devices and components The repair and/or maintenance of devices and components will only be performed when a completely filled out explanation is present. Otherwise, the shipment can be rejected. This explanation may only be filled out and signed by authorized specialist personnel of the operator.
  • Page 32 ABB has Sales & Customer Support The Company’s policy is one of continuous product expertise in over 100 countries worldwide. improvement and the right is reserved to modify the information contained herein without notice. www.abb.com Printed in the Fed. Rep. of Germany (02.2009) ©...

This manual is also suitable for:

Sensyflow eco2

Table of Contents