FEP630, FEH630 ELECTROMAGNETIC FLOWMETER | OI/FEP630/FEH630-EN REV. D
Error no. / Range
Text on the LCD display
F088.012 / electronics
FEB communication error.
EMC disturbance. Call Service.
F086.018 / Electronics
Curr.Out 31 / 32 com error.
Defective Board. EMC
disturbance. Call Service.
F084.010 / electronics
NV data defect.
Data storage irreparable. Call
Service.
F082.013 / Electronics
Incompatible Frontend Board.
Frontend not fit to
Motherboard. Call Service.
F081.025 / electronics
MB voltages outside range.
Defective Motherboard HW. Call
Service.
Function check
Error no. / Range
Text on the LCD display
C078.003 / Config.
Flowrate to zero.
Check digital in terminals.
C076.005 / Config.
All totalizer stopp.
Check digital in terminals.
C074.006 / Config.
Totalizer reset.
Reset of one or more Totalizers.
C072.002 / Config.
Simulation is on.
Simulated values.
Switch off Simulation Mode.
C070.026 / Config.
An alarm is simulated.
Switch off alarm simulation.
Cause
EMC interference on the signal cable.
Wrong signal cable.
Broken motherboard hardware.
EMC interference
Data in SensorMemory corrupt.
Wrong frontend board or motherboard.
Broken motherboard hardware.
Cause
The Digital Input option card is configured to
trigger the 'set flowrate to zero' option and this
event.
The Digital Input option card is configured to
trigger the 'All Totalizer stop' option and this
event.
The Digital Input option card is configured to
trigger the Reset Totalizer option and this event.
The simulation of a process value or an output is
active.
The simulation of an alarm is active.
Remedy
Check signal cables and connection
Please contact the service department.
Please contact the service department.
Please contact the service department.
Please contact the service department.
Replace motherboard.
Please contact the service department.
Remedy
Check terminals of digital input and
configuration.
Check terminals of digital input and
configuration.
Check terminals of digital input and
configuration.
Switch off simulation mode.
Set alarm simulation to 'Off'.