Detailed Explanation Of [Al. 2A Linear Encoder Error 1] - Mitsubishi Electric MELSERVO MR-J4-B Series Instruction Manual

General purpose ac servo/linear encoder
Table of Contents

Advertisement

3. DETAILED EXPLANATION OF [AL. 2A LINEAR ENCODER ERROR 1]

3. DETAILED EXPLANATION OF [AL. 2A LINEAR ENCODER ERROR 1]
If the cause of [AL. 2A Linear encoder error 1] occurrence is not identified, confirm the alarm display details
of MR Configurator2, and contact each manufacturer.
Table 3.1 Detailed explanation of [AL. 2A Linear encoder error 1] for each manufacturer
Detail
Alarm
inform
Mitutoyo
No.
ation
AT343A/AT54_A
No.
2A.1
01
Initialization error
Photoelectric
2A.2
02
capacitive data
mismatch
Photoelectric
2A.3
03
error
2A.4
04
Capacitive error
2A.5
05
CPU error
2A.6
06
EEPROM error
2A.7
07
ROM/RAM error
Optical
2A.8
08
overspeed
As an example, the following describes the detailed information when [AL. 2A Linear encoder error 1] occurs
in the linear encoder AT343A manufactured by Mitutoyo.
[AL. 2A Linear encoder error 1] details
ST74_A
SR_7
Overspeed error
Laser diode error
Encoder
Initialization error
mismatch error
Incremental
Hardware error
signal error
ABS detection
Absolute signal
error
error
Transducer error
Signal strength
System memory
error
error
Signal strength
alarm
Thermal alarm
Speed error
Magnescale
Heidenhain
SR_5/SL710
Initialization error
Scale level error
Encoder warning
INC/ABS data
mismatch error
INC data error
ABS data error
CPU error
Encoder alarm
EEPROM error
Overspeed error
3 - 1
Renishaw
RESOLUTE
RGH26_
Initial error
Level error
Absolute signal
error
Thermal alarm
Overspeed
Overspeed

Advertisement

Table of Contents
loading