Safety instructions and approvals

2.5 Electromagnetic compatibility

2.5
Electromagnetic compatibility
The HMI device fulfils, among other things, the requirements of the EMC laws pertaining to
the European domestic market.
EMC-compliant installation of HMI devices
An EMC-compliant installation of the HMI device and the use of interference-proof cables
form the basis of trouble-free operation. The following documentation applies to the
mounting of the HMI device:
● Description "Directives for interference-free installation of PLCs"
● The manual "PROFINET System Description"
Pulseshaped Interference
The following table shows the electromagnetic compatibility of modules compared to pulse-
shaped interference. These specifications only apply when the HMI device meets the
specifications and directives regarding electrical installation.
Pulse-shaped interference
Electrostatic discharge
conforming to IEC 61000-4-
2:2008
Bursts
(high-speed transient
interference)
in accordance with IEC 61000-
4-4:2004
High-power surge pulses in accordance with IEC 61000-4-5:2005, external protective circuit required
(refer to manual S7-300 PLC, Installation, chapter "Lightning and overvoltage protection").
Asymmetric coupling
Symmetric coupling
26
(http://support.automation.siemens.com/WW/view/de/1064706)"
Tested with
Air discharge: 8 kV
Contact discharge: 6 kV
2 KV power supply cable
2 KV signal cable, > 30 m
1 KV signal cable, < 30 m
2 kV power cable
DC voltage with protective elements
2 KV signal/data cable, > 30 m,
with protective elements as required
1 kV power cable
DC voltage with protective elements
1 KV signal cable, > 30 m,
with protective elements as required
Operating Instructions, 10/2010, A5E03284305-01
Corresponds to test
intensity
3
3
3
3
KP8, KP8F