FM1100 Configurator is divided into 4 main areas: 1 – main button area, 2 –
information area, 3 –settings menu, 4 – parameters and values menu.
Button description:
'Connect' – connects device
'Load' – reads configuration parameters from FM1100 Flash memory.
'Save' – saves configuration parameters to FM1100 Flash memory.
'Load Defaults' – loads default FM1100 settings that later can be modified.
This procedure must be performed before entering new parameters.
'Save to File...' – allows user to save currently entered settings to .XML file, for
later usage.
'Load from File...' – allows user to load configuration saved in .XML extension
file.
'Reset device' – reboots FM1100 and displays processor firmware version.
Additional buttons:
'SIM PIN' – this button is used to enter PIN code if inserted SIM card has
activated PIN code security.
'Add Keyword' / 'Change Keyword' / 'Switch Security Off' – buttons are
used to protect configurator from unauthorized access to configuration.
Keyword is 4 -10 symbol length. If keyword is set, every time user reconnects
FM2200 to USB port, user will be asked to provide valid keyword when connecting
FM1100 to configurator. User is given 5 attempts to enter valid keyword. After
entering valid keyword, counter resets to 5.
If user disconnects FM2200 using 'Disconnect' button and does not
disconnect from USB port, after reconnecting using 'Connect' button,
configurator does not ask for keyword.

5.7 System settings

System settings have 3 configurable parameters:
Deep sleep settings, where user can turn deep sleep on or off.
Analog Input Settings, where user can choose analog input range 10
V or 30 V, depending on needed accuracy (lower range gives higher accuracy
of measurements), and input voltage.
Object Motion Detection Settings, where user can configure 3 ways
how FM1100 will detect stopped movement, and change its working mode (for
working modes, read section 5.12).
Stop Detection Source
Ignition
(recommended)
Msensor
(movement
sensor)
Vehicle on Stop mode
ignition (DIN1) is logic low
internal
movement
does not detect movement
Vehicle Moving mode
if ignition (DIN1) is logic high
sensor
internal
movement
detects movement
sensor