6.3.3 Settings and configurable parameters menu

Every FMB630 profile has seven main groups of parameters:
1. System – main parameters for all device;
2. GSM has 7 subgroups:
a. GPRS
b. GPRS Limits
c. SMS Security
d. SMS Data
e. SMS Events Numbers
f. SMS Events
g. Operator list
3. Features has 7 subgroups:
a. sMode
b. Scenarios
c. Trip
d. Geofencing
e. Auto Geofencing
f. Towing Detection
g. IButton List
4. CAN
5. LVCAN
6. K-Line Data
7. I/O
8. Camera

6.3.4 System Settings

System settings have 2 configurable parameters (Figure 27):
 Sleep settings, where user can disable sleep, turn on or choose deep sleep/online
deep sleep.
 Ignition source settings, for choosing which ignition source prefer to use DIN1, DIN2,
DIN3, DIN4, Movement or External Voltage. While using External Voltage levels must
be set.
Configures COM1 and COM2 ports. User can configure baudrate,
working mode, enable/disable timestamp and change CMD ID(used to
identify from which COM port data came)
COM1 and COM2 start and end byte are filter for TCP Binary link mode.
Configures RS485 settings such as activation of RS485 protocol,
baudrate and working mode.
Allows user to set LLS sensors addresses in preffered order