FULTON Endura+ Series Installation And Operation Manual page 77

Condensing hydronic boilers
Table of Contents

Advertisement

SECTION 4
EDRP-IOM-2019-0212
Bill of Material
Item
Part Number
Description
1
2-12-000012
3/4" NPT Sight Observation Port
2
2-12-000721
029 1/16" Vitton O-Ring 1.625 OD
4
2-12-315008
2" ID x 6" Neoprene Flexible Coupling
6
2-12-315011
EDR+ 6000 Premix / Furnace Gasket
25
2-22-000058
1/2-13 Hex Nut, GR. 2H
34
2-22-315006
2" - 3" Steel Worm Drive Hose Clamp
41
2-22-315039
1/2" Belleville Washer (SS301, 0.519" ID x 1.24" OD x 0.125" THK
42
2-22-315040
1/4-20 x 5/8" Long S.S. Torx Screw
70
2-40-000464
3/4" - 14 NPSM Thermal Barrier for Flame Detector
73
2-40-001107
Siemens LMV2-3 High Sensitivity UV Scanner
76
2-40-315600
EDR+6000 Mesh Burner
89
2-45-315501
O2 Sensor
95
5-10-315310
250 Hz Resonator Capped Tube
96
5-10-315315
EDR+6000 Burner Volume Reducer/Premix Inlet Assembly
107
5-10-315675
EDR+6000 Premix Retainer Plate
110
5-10-315680
EDR+6000 Pilot Assembly
119
5-10-315694
EDR+6000 Pilot Insulation
AN ALTERNATE TOOL MUST BE USED
TO TORQUE THESE TWO NUTS. BE
SURE TO ADJUST TORQUE WRENCH TO
ACCOMODATE THE CHANGE OF GEOMETRY.
INITIAL RELEASE TO FULTON PART NUMBER;
-
UPDATED TITLE BLOCK AND ADDED
SUPERSEDES NOTE
REV
REVISION DESCRIPTION
B.O.M.
REVISION HISTORY
Questions? Please Contact Your Local Manufacturer's Representative
APPLY LOCTITE COPPER C5-A ANTISEIZE
(2-12-000191) TO THREADS WHEN
INSTALLING 02 BYPASS TUBE. TRIM
1" OFF 02 LINE THEN FULLY INSERT
TUBE INTO FITTING, TIGHTEN THE NUT
UNTIL THE TUBE WILL NOT TURN OR MOVE
AXIALLY. THEN TIGHTEN FITTING 1 1/4 MORE
REVOLUTIONS.
BURNER / PREMIX ASSEMBLY
UNLESS OTHERWISE NOTED
DIMENSIONS ARE IN INCHES
FIGURE 26 - EDR+ 4000-6000 BUR ER ASSEMBLY
TOLERANCES
FRACTION &
- - - -
- - - -
- - - -
- - - -
- - - -
WHOLE VALUE
(1) PLACE DEC.
(2) PLACE DEC.
(3) PLACE DEC.
ANGLE
SURFACE FINISH
ELEC. ENG. MECH. ENG
CHECKED
APPROVED
250 MICRO-INCHES
WASHER ORIENTATION DETAIL
(SHOWN PRETORQUE FOR CLARIFICATION)
6
76
6
96
89 TORQUE TO 26 - 33 FT. LBS.
APPLY LOCTITE COPPER C5-A ANTI-SEIZE (2-12-000191),
& TORQUE TO 45 FT. LBS. IN THREE STAGES
25
(SEE WASHER ORIENTATION DETAIL VIEW FOR
41
PROPER BELLEVILLE WASHER
INSTALLATION, (TYP. 14 PLCS.)
This design and drawings
DRAWN BY:
The items shown in this
are proprietary and are the
B. PALMER
drawing may be covered by
exclusive property of
1/8
one or more patents of
Fulton Group N.A., Inc.
CHECKED BY:
Fulton Group N.A., Inc.
0.03
0.015
The corporation does not
M.E.A.
0.005
permit their use except
0.5 DEG
with prior written consent.
B.O.M. REVIEW
THIRD ANGLE PROJECTION
S.M.
6 OF 10
MAINTENANCE
41
BELLEVILLE WASHERS MUST BE INSTALLED
IN THE ORIENTATION SHOWN.
107 (2 PCS.)
APPLY LOCTITE COPPER C5-A ANTI-SEIZE (2-12-000191),
1
TIGHTEN 1.5 - 3.0 TURNS PAST FINGER TIGHT
70
73
APPLY LOCTITE COPPER C5-A ANTI-SEIZE
42
(2-12-000191), & TORQUE TO 60 IN. LBS.,
(TYP. 2 PLCS.)
110
APPLY PARKER SUPER-O-LUBE
2
DURING INSTALLATION
(TORQUE SPEC: 20 IN. LBS.)
34
95
4
34
(TORQUE SPEC: 20 IN. LBS.)
MECH. ENG:
JOB NUMBER:
6/26/2017
P.E.K.
7/11/2017
ELEC. ENG:
PROJECT NAME:
A.M.K.
7/12/2017
7/31/2017
APPROVED BY:
PROJECT MANAGER:
9/27/2017
A.T.F.
7/19/2017
ITEM
PART NUM
1
2-12-000
2
2-12-000
4
2-12-315
6
2-12-315
25
2-22-000
34
2-22-315
41
2-22-315
42
2-22-315
70
2-40-000
73
2-40-001
76
2-40-315
89
2-45-315
95
5-10-315
96
5-10-315
107
5-10-315
110
5-10-315
119
5-10-315
INSTALL 2" DURABLANKET (2-12-880
THE HEAT SHIELD AND THE TOP
FURNACE IN AREAS SHOWN.
NO INSULATION PROTRUDES PA
DIAMETER OF THE TOP FLANGE
ANY CUTOUTS THROUGH TH
ONCE INSULATION IS IN PLACE
(2-12-000196) ON THE EXPOSE
THIS DRAWING SUPERSEDES D
DESCRIPTION:
EDR+ 6000 CONDENS
ASSEMBLY
4-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents