Toshiba TOSVERT VF-AS3 Instruction Manual page 22

Embedded ethernet function
Hide thumbs Also See for TOSVERT VF-AS3:
Table of Contents

Advertisement

[FA38: Communication command 2 from embedded ethernet]
bit
Function
0
Control switching
Electric power quantity
1
reset
2
(Reserved)
3
Braking request (BC)
4
Preliminary excitation
5
(Reserved)
6
Braking answer (BA)
7
Quick deceleration 2
8
Acc/dec switching 1 (*1)
9
Acc/dec switching 2
10
V/f switching 1 (*2)
11
V/f switching 2
OC stall level switching
12
and
Torque limit switching 1
13
Torque limit switching 2
14
Speed gain switching
15
(Reserved)
Note: Set 0 to reserved bit.
(*1): The Acc/Dec switching ORs with Bit 6 of [FA36]. When changing Acc/Dec in four types, set Bit 6 of
[FA36] to "0" and use [FA38].
(*2): The V/f switching ORs with Bit 4 of [FA36]. When changing V/f in four types, set Bit 4 of [FA36] to "0"
and use [FA38].
0
Speed control
Torque control
OFF
Reset
-
-
Normal
Forcibly braked
Normal
Enabled
-
-
Brake applied
Brake released
Normal
Enabled
00: AD mode 1
01: AD mode 2
10: AD mode 3
11: AD mode 4
00: V/f 1
01: V/f 2
10: V/f 3
11: V/f 4
00: Torque limit 1 / OC stall 1
01: Torque limit 2 / OC stall 2
10: Torque limit 3 / OC stall 1
11: Torque limit 4 / OC stall 2
Gain 1
Gain 2
-
-
20
1
-
Electric power quantity (FE76, FE77)
reset
-
-
-
-
-
-
Select Acc/Dec mode 1 - 4 by
combination of two bits.
AD mode 1: ACC, DEC
AD mode 2: F500. F501
AD mode 3: F510, F511
AD mode 4: F514, F515
Select V/f pattern 1 - 4 by combination
of two bits
V/f 1: Pt = setting value, vL, vLv, vb, tHrA
V/f 2: Pt = "0", F170, F171, F172, F182
V/f 3: Pt = "0", F174, F175, F176, F183
V/f 4: Pt = "0", F178, F179, F180, F184
OC stall 1: F601
OC stall 2: F185
Select torque limit 1 - 4 by
combination of two bits
Torque limit 1: F441, F443
Torque limit 2: F444, F445
Torque limit 3: F446, F447
Torque limit 4: F448, F449
Gain 1: F460, F461, F462
Gain 2: F463, F464, F465
-
E6582125
Note

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents