[F897: Parameter writing]
When [F897: Parameter writing] is set to "1", all writing via communication is only done to the RAM. This
parameter can be used when frequently writing to EEPROM supported parameters, but the content of the
parameters return to the values stored in EEPROM each time the inverter is reset.
If you want to temporarily allow storage to EEPROM when [F897] = "1", you can set [FA93] to "1:
Temporarily suppress mode for RAM" to allow writing EEPROM supported parameters.
▼ The [F897] setting is reflected after a reset operation such as power off, so you need power
reset after the setting. In addition, note that if [0897] = "0" is set via communication, the
[F897] parameter does not return to "0: Storage to memory device". To set to "0", modify the
Important
setting from the operation panel.
Parameter writing
[C081 to C096: Device name 1 to 16]
This devide can set the "Device name" of 16 characters.
(These 16 characters are stored in the parameter [C081] to [C096].)
Please set the setting of the device name according to the following rules.
1. The parameter is displayed by the hexadecimal number.
2. Each parameter shows an ASCII character on Guidance function and Web server.
3. The relation between the device name and the parameter is as follows.
Example for Device Name ='VFAS3-2007P'
Chars No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
[F897] = "0"
[F897] = "1"
Parameter
Character (Ex.)
'V'
C081
'F'
C082
'A'
C083
'S'
C084
'3'
C085
'-'
C086
'2'
C087
'0'
C088
'0'
C089
'7'
C090
'P'
C091
C092
-
C093
-
C094
-
C095
-
C096
-
12
[FA93] = "1"
[FA93] = "0"
ASCII (Ex.)
Set point(Ex.)
0x56
0x46
0x41
0x53
0x33
0x2D
0x32
0x30
0x30
0x37
0x50
0x00
0x00
0x00
0x00
0x00
E6582125
Parameter writing
Parameter writing
86
70
65
83
51
45
50
48
48
55
80
0x00
0x00
0x00
0x00
0x00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents