Low Level Sensor Kit, 25E447 - Graco E-Flo SP D200S Installation And Parts Manual

Supply systems
Table of Contents

Advertisement

Kits and Accessories

Low Level Sensor Kit, 25E447

To install the Low Level Sensor:
1. Turn the disconnect switch (M) OFF.
2. Disconnect cable from the empty level sensor (EL).
3. Mount the low level sensor (LL) on the mounting
bracket.
4. Connect the shorter cable to the low level sensor
(LL).
5. Connect the other shorter cable to the empty level
sensor (EL).
6. Connect the low level sensor cable to the A port on
the splitter (SP).
7. Connect the empty level sensor cable to the B port
on the splitter (SP).
8. Connect the original cable to the last port on the
splitter (SP).
9. Raise/lower the low level sensor (LL) to the desired
position to activate the sensor.
10. See the E-Flo SP Software Instructions manual to
set up the low level sensor.
56
LL
EL
SP
SP
3A6331C