Repair

Repair

Disconnect Pump from Platen

The pump is mounted to the platens by different mount-
ing kits. See the Repair Kits on page 53.
55 Gallon Platen
1. Follow the Pressure Relief Procedure on page 22.
2. Turn the disconnect switch (M) to OFF.
3. Remove four hex screws (426), four clamps (427),
and washers (425).
428
TI10422A
Check-Mate Mounting
F
. 22: 55 Gallon Mounting Kit
IG
462
r_255648_313527_35a
Check-Mate Mounting
F
. 23: 20, 30, and 60 liter mounting kit
IG
30
426
425
428
427
463
462
4. Carefully pull pump away to prevent damage to
pump inlet and remove o-ring (428).
20, 30, and 60 Liter Platen
1. Follow the Pressure Relief Procedure on page 22.
2. Turn the disconnect switch (M) to OFF.
3. Loosen two 5/16 in. screws (462) from platen.
4. Carefully pull pump away to prevent damage to
pump inlet. If using a pump with intake adapter,
remove screws (472), adapter (471), and o-rings
(463) from pump inlet.