Tandem Fluid Filter Kit, 25E620 - Graco E-Flo SP D200S Installation And Parts Manual

Supply systems
Table of Contents

Advertisement

Kits and Accessories

Tandem Fluid Filter Kit, 25E620

Fluid Inlet from
Tandem A
Fluid Inlet from
Tandem B
715,
716,
714
717
708
712
713
722
723
724
706
725
705
62
703
702
718,
719,
Fluid Outlet
720
709
704
710
701
Ref.
Part
701
247498 SUPPORT, stand
702
410178 CAP PLUG, vinyl
703
147499 BASE, mounting
704
C30021 BOLT, u
705
210658 VALVE, ball
706
515216 HOUSING, filter
707
C19652 FITTING, bushing, reducing
708
121189 FITTING, elbow, 1"
709
521477 VALVE, ball, 1"
710
121182 ADAPTER, pipe, female
711
102814 GAUGE, press, fluid
712
C19488 FITTING, tee
713
121163 FITTING, cross, 1" npt
714
131526 FITTING, nipple, 1" npt, cs
711
715
101044 WASHER, plain
716
100018 WASHER, lock, spring
707
717
C19853 SCREW, cap, socket hd
718
100023 WASHER, flat
719
100133 WASHER, lock, 3/8
720
100131 NUT, full hex
721
070408 SEALANT, pipe, sst
722
158586 FITTING, bushing
723
16U440 ADAPTER, fitting, pressure sensor
724
15M669 SENSOR, pressure, fluid outlet
725
515222 ELEMENT, filter
726
15Y048 CABLE, M12
To assemble the Tandem Fluid Filter Kit:
1. Ensure the base of the fluid filter stand (701) is level
in all directions. If necessary, use metal shims to
level the base.
2. Secure the base to the floor using anchors that are
long enough to prevent the filter stand from tipping.
3. Install the material hose from tandem A to fluid inlet
A.
4. Install the material hose from tandem B to fluid inlet
B.
5. Install the material hose from the fluid filter outlet to
the dispense valve.
6. Connect the inlet fluid filter pressure transducer to
Port 6 on the tandem A driver for fluid filter
monitoring.
Description
Qty.
1
1
1
2
1
1
2
2
3
2
2
1
2
6
4
4
4
4
4
4
1
2
2
2
1
2
3A6331C

Advertisement

Table of Contents
loading

Table of Contents