Non Controller Operation

The pump can be controlled using an external, user sup-
plied, controller.
NOTE:
When using an external controller, Pump ON (Run)
Time should be set for no longer than 30 minutes.
In most cases, Pump OFF (Rest) Time should be
twice as long as Pump ON (Run) time. If alternative
ON / OFF times are required, contact Graco Cus-
tomer Service for assistance.
Typical Low-Level Output Response with Low-Level Fluid
F
. 22
IG
3A6714C

Low-Level Output Option

Models 25R800, 25R802, 25R807 and 25R809
Pumps without controllers include a Low-Level Output
Option. The low-level signal is monitored across PINS 4
and 5. For the locations and wiring information for PINS
4 and 5, see the Wiring and Installation Diagrams,
page 9.
Model 25R820, 25R822, 25R827 and 25R829
See the Wiring and Installation Diagrams, page 9.
Non Controller Operation