Models

System Pressure

Due to factors such as the dispensing system design,
the material being pumped, and the flow rate, the
dynamic pressure will not reach the rated working (stall)
pressure of the system.
Lower Size
100CS/CM/SS/SM
200CS/CM/SS/SM
250CS/CM/SS/SM
500CS/CM/SS/SM
145SS
180SS
220SS
290SS
430CS/SS/SM
115CS
145CS
180CS
220CS
290CS
Flow Rate Table
Lower Size
100CS/CM/SS/SM
200CS/CM/SS/SM
250CS/CM/SS/SM
500CS/CM/SS/SM
145SS
180SS
220SS
290SS
430CS/SS/SM
115CS
145CS
180CS
220CS
290CS
6
Pump Working (Stall) Pressure Max Dynamic (Run) Pressure
psi
bar
6,000
414
4,200
290
3,400
234
1,600
110
5,600
386
4,500
310
3,700
255
2,800
193
1,900
131
6,000
414
5,600
386
4,500
310
3,700
255
2,800
193
Flow Rate
Flow Rate
(cc/min)
(gpm)
2,500
5,000
6,250
12,500
3,625
4,500
5,500
7,250
10,750
2,875
3,625
4,500
5,500
7,250
MPa
psi
41.4
6,000
29.0
3,905
23.4
3,122
11.0
1,487
38.6
5,204
31.0
4,164
25.5
3,470
19.3
2,602
13.1
1,735
41.4
6,000
38.6
5,204
31.0
4,164
25.5
3,472
19.3
2,602
Outlet Fitting Size
0.66
1 in. NPT female
1.32
1 in. NPT female
1.65
1 in. NPT female
3.30
1-1/2 in. NPT female
0.96
1 in. NPT female
1.19
1 in. NPT female
1.45
1 in. NPT female
1.92
1 in. NPT female
2.84
1-1/2 in. NPT female
0.76
1 in. NPT female
0.96
1 in. NPT female
1.19
1 in. NPT female
1.45
1 in. NPT female
1.92
1 in. NPT female
bar
MPa
414
41.4
269
26.9
215
21.5
103
10.3
359
35.9
287
28.7
239
23.9
179
17.9
120
12.0
414
41.4
359
35.9
287
28.7
239
23.9
179
17.9
3A6331C