Connect Platen
55 Gallon Platen
1. Place o-ring (428) from mounting kit on the platen. If
attached to plate, place displacement pump onto
platen. See F
. 22.
IG
2. Secure pump's intake flange to plate with screws
(426), washers (425), and clamps (427) included in
mounting kit 255392.
20, 30, and 60 Liter Platen
NOTE: Before installing the 20, 30, or 60 liter platen to a
pump with an intake adapter, install adapter and o-ring
from mounting kit using the two set screws. See F
1. Place o-ring (463) from mounting kit on pump
intake. Loosen the pump intake flange screws (462)
and carefully lower pump onto o-ring (463) and
platen.
2. Secure pump's intake flange to plate with screws
(462).
Remove Wipers
See Remove and Reinstall Wipers on page 26.
Install Wipers
See Remove and Reinstall Wipers on page 26.
3A6331C
Remove Displacement Pump
The procedure for removing your displacement pump
depends on which driver and platen your unit uses. Find
your ram unit, driver, and platen below to remove the
displacement pump. Refer to your displacement pump
manual to repair the displacement pump.
If the driver does not require servicing, leave it attached
to its mounting. If the driver does need to be removed,
see Remove Driver on page 33.
D200 3 in. and D200s 6.5 in. Supply Units
. 23.
IG
1. Follow the Pressure Relief Procedure on page 22.
2. Turn the disconnect switch (M) to OFF.
3. See Disconnect Displacement Pump in your
pump package manual.
4. Open the main air slider valve (AA).
5. Raise the driver:
a. Loosen nut (105a) under ram bar and thread it
down the threaded rod (106) to the lift ring
adapter (107) holding the driver. Use wrench on
nut (105) on top of ram bar to raise driver.
105
105a
F
. 24
IG
Repair
106
107
31