All electrical wiring must be done by a qualified elec-
trician and comply with all local codes and regula-
tions.

Location

To properly locate and anchor the supply system, refer
to Dimensions on page 64.
Always lift the supply system at the proper lift locations
(see F
. 1). Do not lift in any other way. Failure to lift
IG
at the proper lift locations can result in damage to the
supply system.
Attach a lifting sling at the proper lift locations. Lift off the
pallet using a crane or a forklift.
NOTE: The lift ring on the driver is only to be used for
replacing the driver. Do not use it to lift the entire sys-
tem.
Position the ram so the driver, disconnect switch, air
controls, and ADM are easily accessible. Ensure that
there is enough space overhead for the ram to raise
fully.
Using the holes in the ram base as a guide, drill holes
for 1/2 in. (13 mm) anchors.
Ensure that the ram base is level in all directions. If nec-
essary, level the base using metal shims. Secure the
base to the floor using 1/2 in. (13 mm) anchors that are
long enough to prevent the ram from tipping.
16
NOTICE

Grounding

The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.
Electric pump: the pump is grounded through the
power cord.
Ram: the ram is grounded through the power cord.
Air and fluid hoses: use only electrically conductive
hoses with a maximum of 500 ft. (150 m) combined
hose length to ensure grounding continuity. Check the
electrical resistance of the hoses. If the total resistance
to ground exceeds 29 megaohms, replace the hose
immediately.
Air compressor: follow manufacturer's recommenda-
tions.
Dispense valve: ground through connection to a prop-
erly grounded fluid hose and pump.
Fluid supply container: follow local code.
Solvent pails used when flushing: follow local code.
Use only conductive metal pails, placed on a grounded
surface. Do not place the pail on a non-conductive sur-
face, such as paper or cardboard, which interrupts the
grounding continuity.
To maintain grounding continuity when flushing or
relieving pressure: hold a metal part of the dispense
valve firmly to the side of a grounded metal pail, then
trigger the valve.