Remove Driver

To avoid serious injury when installing and removing
the driver, make sure the driver is supported at all
times.
1. Follow the Pressure Relief Procedure on page 22.
2. Turn the disconnect switch (M) OFF.
3. See Disconnect Displacement Pump in your
pump package manual.
4. Disconnect power from the driver:
a. Remove the driver housing cover (HC).
b. Disconnect the wires inside the driver housing.
c. Loosen the cord grip (CG).
d. Remove wires from driver housing by pulling
them through the cord grip (CG).
e. Disconnect the cables connected to ports 1-6
on the side of the driver, shown in F
CG
F
. 26
IG
3A6331C
F
. 27
IG
5. Disconnect driver:
a. D200 3 in. and D200s 6.5 in. supply units:
125
. 27.
IG
HC
F
. 28: 55 Gallon Platen
IG
b. D60 3 in. supply units: Remove screws (255)
F
. 29: D60 with Ram
IG
Loosen nut (125) below crossbar. Use wrench
to hold lift ring adapter (127) in place and loosen
threaded rod (126) above crossbar with another
wrench. See F
. 28.
IG
126
and washers (256) from mounting plate (259).
Using a secure hoist, lift the driver from the
mounting plate (259). See F
Repair
125
127
. 29.
IG
259
256
255
33