Power supply
12-24 V AC/DC power supply
115 to 230 V AC mains supply Input voltage range
Input cable for
12/24 V AC/DC and
115 to 230 V AC power supply
Lithium batteries are subject to special transportation regulations according to United Nations
1)
"Regulation of Dangerous Goods, UN 3090 and UN 3091". Special transport documentation
is required to observe these regulations. This may influence both transport time and costs.
10.5
Modbus RTU
Siemens Flow Instruments Modbus RTU specification for add-on modules
Device type
Baud rates
SITRANS MAG 8000
Operating Instructions, 11/2018, A5E03071515-AE
Input voltage range
Power consumption
Isolation
Fuse
Short circuit protection
Conformity
Power consumption
Isolation
Fuse
Short circuit protection
Conformity
Factory-mounted PUR cable
Resistance
Outer diameter
Rated voltage
Testing voltage
Temperature range
Bending radius
Pulling force
Output
Backup battery
Slave
1200, 2400, 4800, 9600, 19 200, 38 400 bits/sec.
12/24 V AC/DC (10 ... 32 V DC)
2 VA
Class II
1000 mA T - Not replaceable
Module is protected from short circuit on the output con‐
nector. Both during mains and backup supply
IEC 61010-1
OIML R 49-1
EMC:
EN 61000-6-3
EN 61000-6-2
115 to 230 V AC, +15% to −20%, 50-60 Hz
2 VA
Class II
250 mA T - Not replaceable
Module is protected from short circuit on the output con‐
nector. Both during mains and backup supply
IEC 61010-1
OIML R49-1
EMC:
EN 61000-6-3
EN 61000-6-2
2 x 1 mm
(brown, blue)
2
Length = 3 m
Sunlight and water
7 mm (0.28")
300 ... 500 V AC
2000 V AC
Fixed laying:
Flexible application:
Min. 28 mm (fixed installation)
Max. 200 N
Female connector
Male connector
Technical data
10.5 Modbus RTU
−40 to +90 °C (-40 to 194 °F)
−30 to +80 °C (-22 to 176 °F)
95