Danfoss VLT AQUA Drive FC 202 Design Manual page 45

Hide thumbs Also See for VLT AQUA Drive FC 202:
Table of Contents

Advertisement

Specifications
®
VLT
AQUA Drive FC 202
High/normal load
(High overload=150% current during 60 s,
normal overload=110% current during 60 s)
Typical shaft output at 400 V [kW]
Typical shaft output at 460 V [hp]
Typical shaft output at 480 V [kW]
Enclosure size
Output current (3-phase)
Continuous (at 400 V) [A]
Intermittent (60 s overload) (at 400 V) [A]
Continuous (at 460/480 V) [A]
Intermittent (60 s overload) (at 460/480 V) [A]
Continuous kVA (at 400 V) [kVA]
Continuous kVA (at 460 V) [kVA]
Maximum input current
Continuous (at 400 V) [A]
Continuous (at 460/480 V) [A]
Maximum number and size of cables per phase (E1h)
- Mains and motor without brake [mm
- Mains and motor with brake [mm
2
- Brake or regeneration [mm
(AWG)]
Maximum number and size of cables per phase (E3h)
- Mains and motor without brake [mm
- Mains and motor with brake [mm
- Load share or regeneration [mm
Maximum external mains fuses [A]
Estimated power loss at 400 V [W]
Estimated power loss at 460 V [W]
3)
Efficiency
Output frequency
Heat sink overtemperature trip [°C (°F)]
Control card overtemperature trip [°C (°F)]
Power card overtemperature trip [°C (°F)]
Fan power card overtemperature trip [°C (°F)]
Active in-rush card overtemperature trip [°C (°F)]
Table 7.3 Electrical Data for Enclosures E1h/E3h, Mains Supply 3x380–480 V AC
1) For fuse ratings, see chapter 10.5 Fuses and Circuit Breakers.
2) Typical power loss is at normal conditions and expected to be within
values are based on a typical motor efficiency (IE/IE3 border line). Lower efficiency motors add to the power loss in the drive. Applies for
dimensioning of drive cooling. If the switching frequency is higher than the default setting, the power losses can increase. LCP and typical control
card power consumptions are included. For power loss data according to EN 50598-2, refer to drives.danfoss.com/knowledge-center/energy-
efficiency-directive/#/. Options and customer load can add up to 30 W to the losses, though usually a fully loaded control card and options for
slots A and B each add only 4 W.
3) Measured using 5 m (16.4 ft) shielded motor cables at rated load and rated frequency. Efficiency measured at nominal current. For energy
efficiency class, see chapter 7.5 Ambient Conditions. For part load losses, see drives.danfoss.com/knowledge-center/energy-efficiency-directive/#/.
MG22B222
Design Guide
N355
HO
315
450
355
E1h/E3h
600
900
540
810
416
430
578
520
2
(AWG)]
5x240 (5x500 mcm)
4x240 (4x500 mcm)
2
(AWG)]
2x185 (2x350 mcm)
2
6x240 (6x500 mcm)
(AWG)]
2
(AWG)]
2x185 (2x350 mcm)
2
4x185 (4x350 mcm)
(AWG)]
800
2)
2), 3)
6178
2), 3)
5322
0.98
0–590 Hz
110 (230)
80 (176)
85 (185)
85 (185)
85 (185)
Danfoss A/S © 01/2018 All rights reserved.
N400
NO
HO
355
355
500
500
400
400
E1h/E3h
658
658
724
987
590
590
649
885
456
456
470
470
634
634
569
569
5x240 (5x500 mcm)
4x240 (4x500 mcm)
2x185 (2x350 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
800
6928
6851
8036
5910
5846
6933
0.98
0–590 Hz
110 (230)
80 (176)
85 (185)
85 (185)
85 (185)
± 15% (tolerance relates to variety in voltage and cable conditions). These
N450
NO
HO
NO
400
400
450
600
550
600
500
500
530
E1h/E3h
745
695
800
820
1043
880
678
678
730
746
1017
803
516
482
554
540
540
582
718
670
771
653
653
704
5x240 (5x500 mcm)
4x240 (4x500 mcm)
2x185 (2x350 mcm)
6x240 (6x500 mcm)
2x185 (2x350 mcm)
4x185 (4x350 mcm)
800
7297
8783
7240
7969
0.98
0–590 Hz
110 (230)
80 (176)
85 (185)
85 (185)
85 (185)
7
7
43