Specifications

6 Specifications

6.1 Clearances, Dimensions, and Weights

6.1.1 Clearances

Observe the minimum clearances listed in Table 6.1 to ensure sufficient air flow for the frequency converter.
When air flow is obstructed close to the frequency converter, ensure adequate inlet of cool air and exhaust of hot air from
the unit.
Enclosure
Enclosure
IP class
type
MH1
IP66/Type 4X
MH2
IP66/Type 4X
MH3
IP66/Type 4X
Table 6.1 Minimum Clearance for Cooling
1) Power ratings relate to NO, see chapter 6.2 Electrical Data.
Enclosure
Maximum depth of hole
type
into adapter plate (A)
[mm]
MH1
3
MH2
4
MH3
3.5
Table 6.2 Information for Screws to Fasten Motor Adapter Plate
®
VLT
DriveMotor FCP 106 and FCM 106 Design Guide
1)
Power
[kW]
3x380-480 V
0.55-1.5
2.2-4.0
5.5-7.5
Maximum height of
screw above adapter
plate (B)
[mm]
0.5
0.5
0.5
1
2
A
B
MG03M102 - 08/2015
Clearance at ends
Motor flange end
30
40
50
1
2
Adapter plate
Screw
Maximum depth of hole into adapter plate
Maximum height of screw above adapter plate
Illustration 6.1 Screws to Fasten Motor Adapter Plate
[mm]
Cooling fan end
100
100
100
47
6