Specifications
A)
Analog output
Number of programmable analog outputs
Terminal number
Current range at analog output
Max. load to common at analog output
Max. voltage at analog output
Accuracy on analog output
Resolution on analog output
1)
Terminal 42 and 45 can also be programmed as digital outputs.
Digital output
Number of digital outputs
Terminal number
Voltage level at digital output
Max. output current at digital output
Max. load at digital output
1) Terminals 42 and 45 can also be programmed as analog output.
Control card, RS-485 serial communication
Terminal number
Terminal number
A)
Control card, 24 V DC output
Terminal number
Maximum load
A)
Relay output
Programmable relay output
Relay 01 and 02
1)
Max. terminal load (AC-1)
on 01-02/04-05 (NO) (Resistive load)
Max. terminal load (AC-15)
1)
on 01-02/04-05 (NO) (Inductive load @ cosφ 0.4)
1)
Max. terminal load (DC-1)
on 01-02/04-05 (NO) (Resistive load)
1)
Max. terminal load (DC-13)
on 01-02/04-05 (NO) (Inductive load)
1)
Max. terminal load (AC-1)
on 01-03/04-06 (NC) (Resistive load)
Max. terminal load (AC-15)
1)
on 01-03/04-06 (NC) (Inductive load @ cosφ 0.4)
1)
Max. terminal load (DC-1)
on 01-03/04-06
(NC) (Resistive load)
Environment according to EN 60664-1
1)
IEC 60947 parts 4 and 5.
A)
Control card, 10 V DC output
Terminal number
Output voltage
Max. load
A)
All inputs, outputs, circuits, DC supplies and relay contacts are galvanically isolated from the supply voltage (PELV) and
other high-voltage terminals.
®
VLT
DriveMotor FCP 106 and FCM 106 Design Guide
Min. terminal load on 01-03 (NC), 01-02 (NO) 24 V DC 10 mA, 24 V AC 20 mA
MG03M102 - 08/2015
Max. error: 0.4% of full scale
68 (P, TX+, RX+), 69 (N, TX-, RX-)
61 Common for terminals 68 and 69
01-03 (NC), 01-02 (NO), 04-06 (NC), 04-05 (NO)
Overvoltage category III/pollution degree 2
2
42, 45
1)
0/4-20 mA
500 Ω
17 V
10 bit
2
1)
42, 45
17 V
6
6
20 mA
1 kΩ
12
80 mA
2
250 V AC, 3 A
250 V AC, 0.2 A
30 V DC, 2 A
24 V DC, 0.1 A
250 V AC, 3 A
250 V AC, 0.2 A
30 V DC, 2 A
50
10.5 V ±0.5 V
25 mA