Engine - Wacker Neuson GPi 3200 Operator's Manual

Inverter generator
Hide thumbs Also See for GPi 3200:
Table of Contents

Advertisement

Maintenance
GPi 3200/4300
Draining the
carburetor
Change the
engine oil
Check
fasteners
Clean the
machine
Store the
machine
4. Reconnect the fuel line to the fuel strainer.
5. Dispose of drained fuel.
1. Place a plastic cloth and a collection container beneath the machine.
wc_gr006674
2. Locate the fuel drain screw (a). The screw is either recessed or exposed
depending on your machine model.
3. Unscrew and remove the fuel drain screw. Fuel will drain from the attached
plastic tube.
4. Collect and dispose of drained fuel.
5. Re-install the fuel drain screw.
See Changing the Engine Oil.
Check the machine for loose or missing fasteners. Tighten or replace as needed.
1. Using a clean, dry shop cloth, wipe the outside of the machine thoroughly to
remove dust and contaminants.
2. Spray the machine with a protectant such as Armor-All®.
NOTICE: Do not use water to clean the machine! Water is corrosive and can per-
manently damage the machine and operating electronics.
Store the machine in a well-ventilated, low humidity area.