Wacker Neuson GPi 3200 Operator's Manual page 43

Inverter generator
Hide thumbs Also See for GPi 3200:
Table of Contents

Advertisement

GPi 3200/4300
Operation
Connecting
and charging
a battery
Follow the procedure below to connect and charge a battery.
1. Connect the positive terminal {e1) (red) on the generator to the positive(+)
battery terminal.
2. Connect the negative terminal {e2) (black) on the generator to the negative(-)
battery terminal.
3. Charge the battery for the recommended length of time prescribed by the
battery manufacturer.
Disconnecting
When the battery is fully charged:
the battery
If the DC
circuit breaker
activates
wc_tx001875gb.fm
1. Disconnect the cable from the negative (-) terminals of the battery and the
generator.
2. Disconnect the cable from the positive ( +) terminals of the battery and the
generator.
The DC circuit breaker
{f)
may activate while a battery is charging. This may occur
for either of the following reasons:
• Defective battery-check the battery before replacing the DC breaker
• Excessive current draw from a large capacity battery or a totally discharged
battery-use an AC battery charger to charge the battery instead of the
generator.