Maintenance
GPi 320014300
5.4
Cleaning the Air Cleaner
When
Clean the air cleaner every 50 hours of operation.
Prerequisite
Description
Procedure
Engine is stopped and cool to the touch
The air cleaner assembly consists of two urethane forms housed inside the air
cleaner body. A clean air cleaner prevents dirt from entering and damaging the
engine.
WARNING
Burn hazard. The engine and exhaust pipe become extremely hot during operation.
11>-
Stop the engine and allow the machine to cool before cleaning the air cleaner.
Follow the procedure below to clean the air cleaner.
wc_gr006670
1. The air cleaner assembly (L) is located on the right side of the machine behind
the control panel. Unhook and remove the air cleaner body cover
(L1).
2. Remove the urethane forms (L2) from the air cleaner body.
3. Rinse the urethane forms with clean water. Squeeze out excess water {do not
twist) and dry the urethane forms thoroughly.
4. Wipe the inside of the air cleaner body with a clean, dry cloth.
5. Reinstall the urethane forms inside the air cleaner body.
6. Reinstall the air cleaner body cover.
W"CKEit
NEUSON
50
wc_tx001240gb.fm
Need help?