Electromagnetic compatibility

See the note in "Applicability of technical specifications (Page 109)".
Interference emission
Immunity to interference
Interference immunity on the
supply cables
Noise immunity on signal lines
Immunity to electrostatic dis-
charge
Immunity to RF interference
Immunity to magnetic fields
SIMATIC IPC627E
Operating Instructions, 12/2018, A5E44297201-AA
EN 61000-6-3, EN 61000-6-4, CAN/CSA CISPR22 class B;
FCC class A
EN 61000-6-1; EN 61000-6-2; KN 35
± 2 kV according to IEC 61000-4-4; burst
± 1 kV according to IEC 61000-4-5; symmetrical surge
± 2 kV according to IEC 61000-4-5; asymmetrical surge
± 1 kV to IEC 61000-4-4; Burst; Length < 3 m
± 2 kV in accordance with IEC 61000-4-4; Burst; length > 3 m
± 2 kV in accordance with IEC 61000-4-5; Surge; length > 30 m
± 6 kV contact discharge in accordance with IEC 61000-4-2
± 8 kV air discharge in accordance with IEC 61000-4-2
10 V/m 80 MHz – 2.7 GHz,
80% AM to IEC 61000-4-3
3 V/m 2.7 – 6 GHz,
80% AM to IEC 61000-4-3
10 V 10 KHz–80 MHz,
80% AM to IEC 61000-4-6
100 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8)