1 General

1 - 6 Resetting the Connecting Order

1

Resetting the Connecting Order (Tower No.)

1 - 6 -
• Connecting order can be set on the Initial Setting
screen. (Refer to [1 - 3 - 2])
Initial Setting
Screen
Connecting Order
51041
10501A1
• If the power is turned on with the incorrect connect-
ing order, LCD panel shows Start Up screen and does
not proceed to the next screen. This section explains
the remedy for that problem.
Start Up Screen
51041
10501B1
1
General
Resetting the Connecting Order
Turn off the power switch.
• DSW on the control board are not required to be
reset. * 1
Press the [Check], [Stop] and [Start]
buttons together, and turn on the
power switch.
* 2
• Keep pressing the three buttons after turn on the
power switch.
Release the buttons after you hear a
beep sound.
- Initial Setting screen appears.
Setup the connecting order correctly.
Press [OK].
- Setup is determined and Information screen appears.
Reboot the machine.
• Turn off the power switch. After 10 seconds, turn on
the power switch again.
- After the Start Up screen, Collating screen appears.
1 - 6 - 1 Resetting the Connecting Order (Tower No.)
Q C - S 3 0 0
Connecting Order and DSW Setting
SW3
QPW-725
QPW-725
CPU
CPU
ROM
SW2
SW1
Tower
Upstream
Middle
Tower
Tower
DSW
SW3
SW4
SW2
SW1
* 1
If the control ROM version is V0.99 or below, set the
DSW for the upstream tower to the setting of the
downstream tower mentioned above.
* 2
If the middle tower is set incorrectly, the display will
not be indicated. Set the DSW on the middle tower
to the upstream/downstream tower setting and then
correct the setting.
0
ROM
SW4
51041
10501C1
Downstream
Tower
1-13
1-13