1 General
1 - 3 Service Screen
1
Description of the Service Screen
1 - 3 -
1
Initial Setting Screen
(1/6)
Information Screen
1
1
1
4 5 6 7
1 - 3 - 1 Description of the Service Screen
51041
10301B1
51041
10301A1
Q C - S 3 0 0
P1
Refer to
[1 - 3 - 3] (Page 1-6)
- Overlap amount to the right delivery. (Single)
- Overlap amount to the left delivery. (Single)
- Set not to detect a double feed when using thick sheets.
- Time that the clutch is being turned on.
P2
Refer to
[1 - 3 - 4] (Page 1-7)
- Overlap amount to the right delivery. (Several)
- Overlap amount to the left delivery. (Several)
- Sensitivity to detect a double feed or a misfeed.
- Set not to detect a misfeed when using thin sheets.
P3
Refer to
[1 - 3 - 5] (Page 1-8)
- Initialize = Reset values to the default setting at factory.
- Speed Limit = Limits the maximum speed.
- Idling = Performs the idling operation.
- Display Indication = Japanese/Pictograph
P4
Refer to
[1 - 3 - 6] (Page 1-9)
- Input Monitor: Monitors the sensor On/Off status.
- Single Operation: Moves the specific part of the
machine singly.
- Amount of light received for the sheet pass sensor.
1-4