Gate Does Not Switch - Horizon Fitness QC-S300 Manual

Table top collator
Hide thumbs Also See for QC-S300:
Table of Contents

Advertisement

2 Troubleshooting
2 - 3 Problem in Machine Operation
4

Gate Does not Switch

2 - 3 -
- When selecting [Information - Service - P4 - Single
Operation] and Y01/Y02 solenoid is turned On/Off,
Plunger of the solenoid tries to move ・・・・・・・・・・・・・
Plunger of the solenoid does not try to move ・・・・・・
Plunger of Y01 Tries to Move
2
Gatre
Drive Link
1
Spring
3
Link
4
Plunger
Y01
Solenoid
Check the followings.
(1) Spring is not removed.
(2) Gate drive link and the gate shaft are correctly
tightened.
(3) Link is correctly tightened.
(4) Plunger moved smoothly.
2 - 3 - 4 Gate Does not Switch
(4/5)
Plunger of Y01 Does not Tray to Move
QC-S300
QC-S300
QPW-725
Main Control Board
CON3
1
2
9
11
Check the followings.
(1) Connector of the gate solenoid is not removed.
(2) Connector of CON3 on QPW-725 is not removed.
(3) Wiring and connection between Y01 and CON3,
pin 1 and 2 on QPW-725 is correct.
(4) Remove the terminals on solenoid Y01. Measure
51041
20304A1
the voltage between terminals (Power source side)
to check if 24 VDC is measure when Y01/Y02 sole-
noid is turned On/Off using the single operation func-
tion.
Main Control Board
Gate Open/Close
BRN
CON
Y01
RED
DC24V
YEL
Solenoid
BLK
1 2 3 4 5 6
Gnd
+ 24V
+24V
G02
51041
20304B1
Check the followings.
(1) Connector of the gate solenoid is not removed.
(2) Connector of CON9 on QPW-734 is not removed.
(3) Wiring and connection between Y01 and CON9,
pin 1 and 2 on QPW-748 is correct.
(4) Remove the terminal of Y01 solenoid. Measure the
voltage between terminals (Power source side) to
check if 24 VDC is measure when Y01/Y02 solenoid
is turned On/Off using the single operation function.
QC-S30
QC-S30
QPW-748
Gate Open/Close
CON9
BRN
1
Y01
RED
2
Solenoid
X07
D/YEL
+24V
BL Terminal
GND
G02
2-14
51041
20304C1