Unitronics UMI-B1 UL Series Operation Manual page 77

Table of Contents

Advertisement

UMI-B1 UL Series Inverter
Function
Name
code
Cooling
P08.39
fan running
mode
PWM
P08.40
selection
Over
P08.41
commissio
n selection
Keypad
data
P08.42
control
setting
Detailed instruction of parameters
Setting range: 200.0–2000.0V
In order to prevent customers set the value is
too large, it is recommended setting range:
Voltage
Range
375–400V
0: Rated running mode
1: The fan keeps on running after power on
0x00–0x21
LED ones: PWM mode selection
0: PWM mode 1, three-phase modulation and
two-modulation
1: PWM mode 2, three-phase modulation
LED tens: low-speed carrier frequency limit
mode
0: Low-speed carrier frequency limit mode 1,
the carrier frequency will limit to 2k if it
exceeds 2k at low speed
1: Low-speed carrier frequency limit mode 2,
the carrier frequency will limit to 4k if it
exceeds 4k at low speed
2: No limit
LED ones
0: Invalid
1: Valid
LED tens (for factory commissioning)
0: Light overcommission; in zone 1
1: Heavy overcommission; in zone 2
0x0000–0x1223
LED ones: frequency enable selection
0: Both ∧/∨ keys and analog potentiometer
adjustments are valid
1: Only ∧/∨ keys adjustment is valid
2: Only analog potentiometer adjustments is
valid
3: Neither ∧/∨ keys nor digital
potentiometer adjustments are valid
LED tens: frequency control selection
0: Only valid when P00.06=0 or P00.07=0
220V
460V
715–780V
75
Function parameters
Default
Modify
value
0
0x01
0x00
0x0000

Hide quick links:

Advertisement

Table of Contents
loading