Unitronics UMI-B1 UL Series Operation Manual page 55

Table of Contents

Advertisement

UMI-B1 UL Series Inverter
Function
Name
code
of the input
terminals
Switch
P05.11
filter time
Virtual
P05.12
terminals
setting
Terminals
control
P05.13
running
mode
Detailed instruction of parameters
Set the bit to 0, the input terminal is anode.
Set the bit to 1, the input terminal is cathode.
BIT8
BIT7
HDI
S8
BIT3
BIT2
S4
S3
The setting range: 0x000–0x1FF
Set the sample filter time of S1–S4 and HDI
terminals. If the interference is strong,
increase the parameter to avoid wrong
operation.
0.000–1.000s
0x000–0x1FF (0: Disabled, 1:Enabled )
BIT0: S1 virtual terminal
BIT1: S2 virtual terminal
BIT2: S3 virtual terminal
BIT3: S4 virtual terminal
BIT4: S5 virtual terminal
BIT5: S6 virtual terminal
BIT6: S7 virtual terminal
BIT7: S8 virtual terminal
BIT8: HDI virtual terminal
Set the operation mode of the terminals
control
0: 2-wire control 1, comply the enable with the
direction. This mode is widely used. It
determines the rotation direction by the
defined FWD and REV terminals command.
FWD
K1
REV
K2
COM
1: 2-wire control 2; Separate the enable from
the direction. FWD defined by this mode is
the enabling ones. The direction depends on
the state of the defined REV.
BIT6
BIT5
S7
S6
BIT1
BIT0
S2
S1
Running
FWD
REV
command
OFF
OFF
Stopping
Forward
ON
OFF
running
Reverse
OFF
ON
running
ON
ON
Hold on
53
Function parameters
Default
Modify
value
BIT4
S5
0.010s
0x000
0