Function parameters
Function
Default
Name
Detailed instruction of parameters
Modify
code
value
P00.03)
4: High-speed pulse HDI setting
The frequency is set by high-speed pulse
terminals. UMI-B1 UL series inverters provide
1 high speed pulse input as the standard
configuration. The pulse frequency range is
0.00–50.00kHz.
100.0% of the high speed pulse input setting
corresponds to the maximum frequency in
forward direction (function code P00.03) and
-100.0% corresponds to the maximum
frequency in reverse direction (function code
P00.03).
Note: The pulse setting can only be input by
multi-function terminals HDI. Set P05.00 (HDI
input selection) to high speed pulse input,
and set P05.49 (HDI high speed pulse input
function selection) to frequency setting input.
5: Simple PLC program setting
The inverter runs at simple PLC program
mode when P00.06=5 or P00.07=5. Set P10
(simple PLC and multi-step speed control) to
select the running frequency running
direction, ACC/DEC time and the keeping
time of corresponding stage. See the function
description of P10 for detailed information.
6: Multi-step speed running setting
The inverter runs at multi-step speed mode
when P00.06=6 or P00.07=6. Set P05 to
select the current running step, and set P10
to select the current running frequency.
The multi-step speed has the priority when
P00.06 or P00.07 does not equal to 6, but the
setting stage can only be the 1–15 stage. The
setting stage is 1–15 if P00.06 or P00.07
equals to 6.
7: PID control setting
The running mode of the inverter is process
PID control when P00.06=7 or P00.07=7. It is
30