5 Function parameters

The function parameters of UMI-B1 UL series inverters have been divided into 30
groups (P00–P29) according to the function, of which P18–P28 are reserved. Each
function group contains certain function codes applying 3-level menus. For example,
"P08.08" means the eighth function code in the P8 group function, P29 group is factory
reserved, and users are forbidden to access these parameters.
For the convenience of function codes setting, the function group number corresponds
to the first level menu, the function code corresponds to the second level menu and the
function code corresponds to the third level menu.
1. Below is the instruction of the function lists:
The first column "Function code": codes of function parameter group and parameters;
The second column "Name": full name of function parameters;
The third column "Detailed illustration of parameters": Detailed illustration of the
function parameters
The fourth column "Default value": the original factory set value of the function
parameter;
The fifth column "Modify": the modifying character of function codes (the parameters
can be modified or not and the modifying conditions), below is the instruction:
"○": means the set value of the parameter can be modified on stop and running state;
"◎": means the set value of the parameter can not be modified on the running state;
"●": means the value of the parameter is the real detection value which can not be
modified.
Function
Name
code
P00 Group Basic function group
Speed
P00.00
control
mode
Detailed instruction of parameters
0: SVC 0
.No need to install encoders. Suitable in
applications which need low frequency, big
torque for high accuracy of rotating speed
and torque control. Relative to mode 1, it is
more suitable for the applications which need
small power.
1: SVC 1
1 is suitable in high performance cases with
the advantage of high accuracy of rotating
27
Function parameters
Default
Modify
value
1