Unitronics UMI-B1 UL Series Operation Manual page 41

Table of Contents

Advertisement

UMI-B1 UL Series Inverter
Function
Name
code
frequency
is above 0)
Hibernatio
P01.20
n restore
delay time
Restart
P01.21
after power
off
The
waiting
time of
P01.22
restart
after power
off
P01.23 Start delay The function determines the brake release
Detailed instruction of parameters
again and it lasts for the time set by P01.20,
the inverter will come back to the running
state automatically.
This function code determines the hibernation
delay time. When the running frequency of
the inverter is lower than the lower limit one,
the inverter will stop to stand by.
When the set frequency is above the lower
limit one again and it lasts for the time set by
P01.20, the inverter will run automatically.
Set frequency
t1<t3, so the inverter does not work
t1+t2=t3, so the inverter works
t3=P01.20
Running
Setting range: 0.0–3600.0s (valid when
P01.19=2)
This function can enable the inverter start or
not after the power off and then power on.
0: Disabled
1: Enabled, if the starting need is met, the
inverter will run automatically after waiting for
the time defined by P01.22.
The function determines the waiting time
before the automatic running of the inverter
when powering off and then powering on.
Output frequency
Running Power off
Setting range: 0.0–3600.0s (valid when
P01.21=1)
t1
t2
t3
Time
Dormancy
Running
t1=P01.22
t2=P01.23
t1
t2
Running
Power on
39
Function parameters
Default
Modify
value
0.0s
0
1.0s
t
0.0s