The screen shows the messages <Warning 15> and <Height guard is off>. There
is also an acoustic signal when raising or lowering to alert the operator to the fact
that this servicing operation is enabled.
Note
n
This setting is active for 2 minutes and the height difference guard is then
automatically switched back <ON> again. The height difference guard can be
switched back <ON> again from the service menu. This setting is not stored in
memory, so height monitoring is always switched <ON> after the system is switched
off and on again.

7.3.6 Odd number of columns

This option allows odd numbers of columns to be accepted too. By default, <Odd
number of columns> is <OFF>.
This helps avoid situations where a column is not properly registered or missed out
accidentally while columns are being linked.
This setting can only be switched <ON> in specific cases and when expressly
requested by the customer.

7.3.7 Height dimension

This setting can modify how the height is read on the screen.
You can choose between centimeters <cm> or inches <">.

7.3.8 Language

This setting allows the language used on the screen to be selected. There is a
choice of:
Table 7.1 Language settings
Setting
NED
ENG
DEU
FRA
ESP
POL
POR
ITA
Operating instructions (Version 0)
Service and troubleshooting
Language
Dutch
English
German
French
Spanish
Polish
Portugese
Italian