Fault Messages - stertil-KONI ST1075-FBF Installation, Operation And Maintanance Instructions

Mobile column lift
Table of Contents

Advertisement

7

7.5.3 Fault messages

If there is a fault, the radio network will be cancelled and a red light (FAULT) will be
continuously illuminated on the front panel. On the screen, it looks like this:
No communication with
the master column
Figure 7.7 Fault message
Before the system can be restarted (see
page
34), the fault must be cancelled.
Table 7.4 Fault messages
Code
71
72
77
Operating instructions (Version 0)
Service and troubleshooting
FAILURE 71
Screen text
Possible cause
No
Distance between
communication
the columns too
with the master
great; time interval
column.
between messages
too great.
No
Distance between
communication
the columns too
with a slave
great; time interval
column.
between messages
too great.
Front key.
A push button was
being pressed during
startup.
5.2.2 "Starting and identification" on
Solution
Reboot the system. If the fault
occurs again, contact
technical services.
Reboot the system. If the fault
occurs again, contact
technical services.
Reboot.
63
ST 1075

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents