7.3.9 Motor run time hours

This shows the time (in hours and minutes) that the motor has run for.
The time is stored by the controller and cannot be reset. If a new PCB is fitted,
though, the measurement will start at zero again.

7.3.10 System run time

This shows the time (in days and hours) that the controller has run for.
The time is stored by the controller and cannot be reset. If a new PCB is fitted,
though, the measurement will start at zero again.

7.3.11 Long distance

This function is disabled <OFF> by default.
This is the recommended position for indoor use.
For long distance between columns, enabling it <ON> is recommended.
In contrast to the other service settings, this particular setting must be made for each
column individually.

7.3.12 Weight dimension (optional)

This setting shows the representation of the weight on the screen.
The choices are:
• kg = kilograms
• lbs = pounds
• bar = kg/cm
• uA = microamps (the measurement range of the pressure transmitter is 0 to
20,000 uA)
The load is derived from the hydraulic pressure in the lifting cylinder.
Note
n
If the lifting fork is resting on the pawl, the pressure drops and the load indicator
shows 0 lbs.

7.3.13 Weight category (optional)

In order for the weight to be displayed correctly, the correct type of vehicle lift must
be entered:
• 082 = ST1082 (cylinder diameter. 70 mm)
• 073 = ST1073 (cylinder diameter. 63 mm)
• 060 = ST1060 (cylinder diameter. 55 mm)