7.5.2 Error reports

When there is an error, further operations are locked out. This is shown on the
screen as follows:
Other column has an
error/failure
Figure 7.6 Error report
The error has to be cancelled first.
Pressing <SELECT> and <UNLOCK> continuously for 2 seconds resets the system.
Table 7.3 Troubleshooting
Code
04
05
06
07
08
09
10 -
17
Operating instructions (Version 0)
ERROR 5
Screen text
Possible cause
Column
Another PCB is
software
installed.
version too low.
Other column
Another column has
has an
a problem.
error/fault.
Status error on
Only occurs on
another
column 1: other
column.
column(s) are not
carrying out
instructions.
Output UP too
UP button stuck.
long activated.
Output DOWN
DOWN button stuck. Check the push button.
too long
activated.
Output
UNLOCK button
UNLOCK too
stuck.
long activated.
Turn off limit
Hydraulic leak in one
columns 1 to 8.
of the columns: this
can be recognized by
one of the columns
lagging behind when
raising.
Solution
Fit a PCB with the right
software.
Check the screens on the
other columns.
Restart the system. If the fault
occurs again, contact
technical services.
Check the push button.
Check the push button.
Cancel the fault by pressing
<SELECT> and <UNLOCK>
for 2 seconds.