Chrono-Thermostat Or Room Thermostat For; The Zone; H (Mm); No No - Sime MURELLE REVOLUTION 30 User, Installation And Servicing Instructions

Wall-mounted hybrid condensing boiler
Hide thumbs Also See for MURELLE REVOLUTION 30:
Table of Contents

Advertisement

– turn the
encoder to select the "Climatic curve " row
Req. from ext. TA
Room probe run
Room probe modul.
Ext. probe modul.
Weather comp.curve
ˆ
Esc
– press the
encoder to confirm the highlighted "Row"
and access the modifiable parameters.
Req. from ext. TA
Room probe run
Room probe modul.
Ext. probe modul.
Weather comp.curve
ˆ
Esc
– turn the
encoder to select the preferred climatic curve
(from 1 to 9) according to the system requirements
– press the
encoder to confirm the selection
– press the
Esc
m
CAUTION
The submenu "Hybrid func. status" is read-only.

5.14.2 Chrono-thermostat or room thermostat for

the zone

The chrono-thermostat or room thermostat for the zone must
be connected to terminals AT2 on the boiler control panel (gas
side).
To set the MULTIZONE system configuration, operate the main
control panel as described below.
From the "Main screen" :
Zone
Menu
– press the
Mode
select screen
– turn the
encoder to select "Winter" mode
46
Zone heating
NO
YES
YES
YES
4.0
BACK
Zone heating
NO
YES
YES
YES
4.0
BACK
button to go back to the "Main screen".
Thu 18 Set 2014
10:30
Off
Mode
button to access the "Function mode"

Fig. 77

– press the
click
– turn the
– press the
"Rows"
Fig. 78
– turn the
– press the
click
go to the modifiable area
– turn the
– press the
click
Fig. 79
– press the
and return to the "Main screen" .
Off
Summer
Winter
Hot water
MAN 40°C
Heating
MAN 20.0°C
Holiday function
OFF
Esc
Back
encoder to confirm and access the "Rows"
encoder to select "Heating"
encoder to confirm "Heating" and access the
Summer
Winter
Off
Hot water
MAN 40°C
Heating
MAN 20.0°C
Holiday function
OFF
Esc
Back
encoder to select "Function mode"
encoder to confirm the "Function mode" and
Heating
Function Mode
MAN
Set AUTO comfort
20.0°C
Set AUTO reduced
18.0°C
Set MAN
20.0°C
Program. Time
[...]
Esc
Back
encoder to select "OFF"
encoder to confirm
Heating
Function Mode
MAN
Set AUTO comfort
20.0°C
Set AUTO reduced
18.0°C
Set MAN
20.0°C
Program. Time
[...]
Esc
Back
button to complete the modification
Esc
Fig. 80
Fig. 81
Fig. 82
Fig. 83

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MURELLE REVOLUTION 30 and is the answer not in the manual?

Questions and answers

Table of Contents