6.4

Parameter setting and display

To access the parameters menu from the "Main screen" :
Zone
Menu
– press the
Menu
screen
– turn the
encoder to select the "TECHNICAL" menu
GENERAL SETTINGS
INFORMATION
TECHNICAL
Esc
– press the
click
encoder to access the modifiable area. The
following screen is displayed:
Confirm operation?
Cancel
– press the
Cancel
menu
– press the
Confirm
State hybrid operation
Zone heating
Ht-boiler adjust. param.
Hot water
Boiler parameters
ˆ
Esc
60
Thu 18 Set 2014
10:30
Off
Mode
button to view the "Menu" selection
MENU
[...]
[...]
[...]
Back
CONFIRM REQUEST
Confirm
button to go back to the "TECHNICAL"
button to access the submenus
TECHNICAL
[...]
[...]
[...]
[...]
[...]
Back
– turn the
– press the
click
and access the modifiable parameters area.
NOTE
: The parameters below can be found in the submenu
"HP-Boiler adjustment parameters".
Type
No.
Description
ΔT ON heating
P
110
request
Fig. 145
ΔT OFF heating
P
120
request
Outdoor probe
temperature
P
130
for boiler ON to
boost
Time 1 boiler ON
P
140
(to support)
Time 2 boiler ON
P
150
(to support)
ΔT ON heating
P
160
boost request
ΔT OFF heating
P
170
boost request
ΔT set for heat
P
180
pump
Time 3 boiler
P
190
ON (restart
Fig. 146
prevented)
Outdoor probe
P
510
temp. for heat
pump OFF
Boiler activation
P
520
to boost heating
Domestic hot
P
530
water activation
Heat pump acti-
P
540
vation
HP maximum
P
550
limit
Time Programming
Once the HP-Boiler parameter setting is complete::
– press the
Fig. 147
– turn the
submenu
The following screen appears when the
pressed as confirmation:
Fig. 148
encoder to select the required submenu
encoder to confirm the selected submenu
Range
U/M
0
°C
....10
0
°C
....10
-5
°C
....15
0
min
....60
0
min
....60
-20
°C
...20
-20
°C
...20
-10
°C
...10
0 ...30
min
-15
°C
...0
Off/
-
On
Off/
-
On
Off/
-
On
30
°C
...55
[......]
-
button
Esc
encoder to select the "Boiler parameters"
ENTER ACCESS CODE
Code:
0 0 0 0 0
Cancel
Confirm
Step
Default
1
1
1
4
1
7
1
20
1
5
1
2
1
1
1
8
1
3
1
-7
-
On
-
On
-
On
1
47
-
-
encoder is
Fig. 149