13. Operator's Troubleshooting
Problem
Platform will not go up
or down.
Platform will not drive
forward or reverse
when raised.
page 13 - 2
Cause
Engine is not running.
Switches set wrong
(Lift Indicator light is lit).
S3970RT / S3370RT /
S2770RT is not level.
(Lift Indicator light is not lit
and the Level Sensor
Alarm is sounding).
The Stabilisers are not
properly set.
(Lift Indicator light is not
lit).
Unit not level.
Articulating axle operated.
Rev A
Remedy
Start the engine from the control station
where you will operate the S3970RT /
S3370RT / S2770RT.
For ground control operation:
Ground/Platform Selector = Ground
For platform control box operation:
Ground/Platform Selector = Platform
Lift/Drive Selector
Squeeze and hold the Safety Control then
push Joystick Controller forward to go up
or pull it backward to go down.
Use the stabilisers to level the S3970RT /
S3370RT / S2770RT.
If you are using the stabilisers, one (1) or
more of them is not down quite far
enough. Lower each stabiliser a few
inches more to be sure each is firmly in
contact with the ground.
If you are not using the stabilisers, one (1)
or more of them is not fully up. Raise each
stabiliser completely up.
Situation normal, lower platform to drive.
S3970RT, S3370RT & S2770RT – 13865-1