11. Options
Figure 11.11 - LPG Fuel Tank Replacement
To re place an LPG tank: Close the valve (see
Fig ure 11.11). Man u ally dis con nect the fuel hose at
the knurled ring and lift the tank out.
NOTE:
LPG fuel installations are usually fitted post
production and may vary from machine to
machine. It is the operator's responsibility
therefore, to be aware of how the system is
installed on their individual machine and know
which gauge, (horizontal or vertical) to read.
n Operating From the Ground Control
Box
Be fore you be gin to op er ate the S3970RT /
S3370RT / S2770RT from the ground con trol box,
a qual i fied op er a tor must per form the Daily In spec -
tion and Main te nance as de scribed in chap ter 7, of
this man ual
To start a gas o line, LP-only, or dual-fuel (LP & gas -
o line) en gine from the ground con trol box do the
fol low ing:
Figure 11.12
page 11 - 4
Set the Battery switch (see Figure 11.12)
to on.
Figure 11.13
2. Set the Emergency Stop switch to on
(out).
3. Set the Ground/Platform Selector switch
to ground (down) (see Figure 11.13).
Figure - 11.14
4. For LP operation:
Completely open the valve (see Figure
11.14) on top of the LP tank (unscrew
counterclockwise until it stops).
Rev A
S3970RT, S3370RT & S2770RT – 13865-1