Figure 11.15
5. For a dual-fuel en gine:
Set the Fuel switch (not shown here) to LP
fuel or gas o line fuel de pend ing on which you
want to use.
6. If the engine is cold, press and hold the
Choke switch … (see Figure 11.15) during
the next step.
7. Press the start switch † down and hold it
there until the engine starts or for 20
seconds, whichever comes first. When the
engine starts, release both the start switch †
and the choke switch … (see Figure 11.15)
CAUTION
If the engine does not start in 20 seconds,
release the start switch † and the Choke
switch … then wait 60 seconds before trying
to start the engine again.
n Operating From The Platform Control
Box
Be fore you be gin to op er ate the S3970RT /
S3370RT / S2770RT from the plat form con trol box,
a qual i fied op er a tor must per form the Daily In spec -
tion and Main te nance as de scribed in chap ter , of
this man ual
To start a gas o line, LP-only, or dual-fuel (LP & gas -
o line) en gine from the plat form con trol box do the
fol low ing:
S3970RT, S3370RT & S2770RT – 13865-1
Figure 11.16
1. Set the Battery switch  to on (see Figure
11.16).
Figure 11.17
2. Set the Emergency Stop switch € to on
(out) (see Figure 11.17).
3. Set the Ground/Platform Selector switch 
to platform (up) (see Figure 11.17).
Figure 11.18