Do you have a question about the S3219E and is the answer not in the manual?
Questions and answers
Arjun thaoa
March 10, 2025
During the run machine has suddenly stop could you please provide me, What is the exactly problem on this machine?
1 comments:
Mr. Anderson
March 10, 2025
A Snorkel S3219E machine could suddenly stop during operation due to the following reasons:
1. Emergency Stop (E-Stop) Activated – If the third E-stop is pressed, the machine will not operate at all. 2. Enable Button Not Pressed – The enable button must be pressed for operation. If no function is performed for about 5 seconds, it must be repressed. 3. Operator Pushed Against Snorkel Guard – If the operator is involuntarily pushed against the spring-loaded Snorkel Guard rail, machine functions are disabled. 4. Exceeding Platform Capacity – If the weight on the platform exceeds the rated work load, the machine may stop to prevent tipping over. 5. Battery or Electrical Issues – If battery cables or control modules are disconnected, the machine may lose power. 6. Safety System Activation – Various safety systems, including limit switches and control interlocks, may disable operation if a fault is detected.
Releasing the E-stop, repressing the enable button, or addressing safety conditions may be required to resume operation.
SAFETY RULES Warning All personnel shall carefully read, understand and follow all safety rules and operating instructions before operating or performing maintenance on any Snorkel aerial work platform. Electrocution Hazard Tip Over Hazard Collision Hazard Fall Hazard NEVER elevate the platform...
Fall Restraint Lanyard Anchor Points All fall restraint lanyard anchor points on Snorkel aerial work platforms have been tested with a force of 61.3 KN (3,650 lbs) per person. See below examples of anchor points used on Snorkel machines with their corresponding per person rating.
Introduction Introduction When contacting Snorkel for service or parts information, be sure to include the MODEL and SERIAL NUMBERS This manual covers the S3219E, S3220E, S3226E, from the equipment nameplate. Should the nameplate S4726E, and S4732E Aerial Work Platforms. be missing, the SERIAL NUMBER is also stamped on the front of the chassis.
Refer to the machine specifications for the level sensor will stop the lift, drive and lower functions and the alarm factory setting. remove the load in excess of rated capacity and cycle S3219E/S3220E/S3226E/S4726E/S4732E – 1500842...
Controls to drive the aerial platform are located on the upper control panel only. The diagnostic center LCD display is located in the hy- draulic tray next to the fluid reservoir (refer to Figure 4). S3219E/S3220E/S3226E/S4726E/S4732E – 1500842...
Joystick to control platform lift, drive, and steer The emergency stop is a two-position red push button. Horn button Battery condition indicator Push the button inward to disconnect power to all Platform overload protection light control circuits. Twist the button to restore power. S3219E/S3220E/S3226E/S4726E/S4732E – 1500842...
To steer to the right, engage the interlock switch on and structural damage, loose or missing hardware, the joystick and hold down the right side of the steer hydraulic leaks, damaged control cable and loose switch. wire connections. S3219E/S3220E/S3226E/S4726E/S4732E – 1500842...
4. Visually inspect the elevating assembly, lift cylinder, and hoses for cracked welds and structural damage, loose hardware, hydraulic leaks, loose wire connec- tions, and erratic operation. Check for missing or loose parts. 5. Hold the ground operation switch downward. Test S3219E/S3220E/S3226E/S4726E/S4732E – 1500842...
Do not elevate the platform tery trays. with the fold down rails lowered. Use extreme care when moving the aerial platform while the fold down 3. Place the battery disconnect switch in the on position. rails are lowered. S3219E/S3220E/S3226E/S4726E/S4732E – 1500842...
Do not drive an elevated aerial platform on the emergency stop button at the upper controls to return soft, uneven, or sloping surfaces. Do not drive on to normal operation. grades that exceed 25 percent. S3219E/S3220E/S3226E/S4726E/S4732E – 1500842...
The platform guardrails may be folded down to pass the In high the machine will travel up to 3.2 km/h (2 mph) when machine under low height obstructions. the platform is raised less than 2.4 m (8 ) and up to 0.6 km/h S3219E/S3220E/S3226E/S4726E/S4732E – 1500842...
Need help?
Do you have a question about the S3219E and is the answer not in the manual?
Questions and answers
During the run machine has suddenly stop could you please provide me, What is the exactly problem on this machine?
A Snorkel S3219E machine could suddenly stop during operation due to the following reasons:
1. Emergency Stop (E-Stop) Activated – If the third E-stop is pressed, the machine will not operate at all.
2. Enable Button Not Pressed – The enable button must be pressed for operation. If no function is performed for about 5 seconds, it must be repressed.
3. Operator Pushed Against Snorkel Guard – If the operator is involuntarily pushed against the spring-loaded Snorkel Guard rail, machine functions are disabled.
4. Exceeding Platform Capacity – If the weight on the platform exceeds the rated work load, the machine may stop to prevent tipping over.
5. Battery or Electrical Issues – If battery cables or control modules are disconnected, the machine may lose power.
6. Safety System Activation – Various safety systems, including limit switches and control interlocks, may disable operation if a fault is detected.
Releasing the E-stop, repressing the enable button, or addressing safety conditions may be required to resume operation.