5. Automatic Shut-offs and Circuit Breakers
q

Stabilisers

The S3970RT / S3370RT / S2770RT can not be
driven un less the sta bi lis ers are com pletely up. If
you have just raised the sta bi lis ers but the
S3970RT / S3370RT / S2770RT will not drive, dou -
ble check to be sure all four (4) sta bi lis ers are com -
pletely up.
n Fuses
Figure 5.4 - Fuses
There are four (4) fuses on a stan dard S3970RT /
S3370RT / S2770RT, that are accessable to the
op er a tor. (The fuses are lo cated on the en gine cab -
i net wall un der the ra di a tor over flow bot tle). The
pur pose is to pro tect the elec tri cal cir cuits from
over loads. If a fuse blows in ves ti gate the cause.
When sat is fied the fault no longers oc curs re place
the fuse with one of the same ratingthen at tempt to
use the S3970RT / S3370RT / S2770RT.
If the fuse blows again,take the S3970RT /
S3370RT / S2770RT out of ser vice and re fer the
prob lem to a qual i fied trained ser vice tech ni cian for
re pair.
q

RCD / ELCB outlet (option)

Figure 5.5 - RCD/ELCB Outlet
page 5 - 2
The RCD (Re sid ual Cur rent De vice) is lo cated at
the ground and will pro tect against short cir cuits to
earth. When there is a short cir cuit the RCD will
shut down the 230v AC power to the plat form out -
let.
To re set the out let dis con nect the power tool lead
from the plat form box and re set the RCD at the
ground.
If the prob lem per sists call a trained ser vice tech ni -
cian.
Rev A
S3970RT, S3370RT & S2770RT – 13865-1