Programming The 580009 Contrast Sensor - Avery Dennison SNAP 500 User Manual

Hide thumbs Also See for SNAP 500:
Table of Contents

Advertisement

102
Release the TEACH button. If the Q light flashes rapidly, the sensor did not program
correctly. If the process fails repeatedly, the sensor may not be lined up correctly with the
sense mark, or there may not be enough contrast between the background and the sense mark.
Move the material so that the sense mark moves back and forth under the sensor. The Q light
on the sensor should flash when the sense mark passes under the sensor.
Move the configuration switch to either the RUN L or RUN D position, depending on the
sense mark.

Programming the 580009 Contrast Sensor

The figure below shows the control panel for the 58009 Contrast Sensor. The configuration
switch has three positions:
Q1 – Teaching mode
Run – Run mode
Run Delay – Do not use
To teach the sensor, thread the printer with the stock to be used. Position the material so that
a sense mark is just to the left of the sensor position. Adjust the sensor position across the
web so that the sensor lines up with the sense mark.
Set the control switch on the sensor to the Q1 position. Press and hold the TEACH button
while using the stock advance knob to move the sense mark under and past the sensor.
All manuals and user guides at all-guides.com
index finger, while applying back tension to the supply roll
with the left thumb. This ensures that the stock is in the same
position that it will be when the printer is running.