2. Measure voltage between terminals on the harness side connector when each function switch is ON (switch is
depressed).
Function switch
Cruise Main
Cancel
Set/Coast
Resume/Accel
3. If not within specification, replace switch.
Terminal
RH 3-4
RH 3-5
RH 3-5
RH 3-5
Voltage
-
0.0V ± 0.22V
1.5V ± 0.22V
3.0V ± 0.22V