K.5 Principles of calculation

K.5.1 Fuel parameters
Fuel
CO
2 max
Natural Gas 11,90
Light Oil
15,50
Heavy Oil
15,80
Coal
18,40
Anthracit
19,10
Coke
20,60
Propane
13,80
Butan
4,10
Test gas
0,00
Diesel
15,60
Petrol
15,10
K.5.2 Calculation formulae
Carbon dioxide:
Efficiency referred to Gross Efficiency:
(
(
K
Effg = 100 -
Efficiency referred to Nett Efficiency:
(
(
K
net
Effn= 100 -
O
K
2 base
gr
3,00%
0,35%
3,00%
0,48%
3,00%
0,51%
7,00%
0,62%
7,00%
0,67%
7,00%
0,75%
3,00%
0,42%
3,00%
0,43%
0,00%
0,00%
3,00%
0,49%
3,00%
0,46%
CO
2max
CO
=
2
x (FT - AT)
)
(
(MH
gr
+
CO
2
(MH
)
(
x (FT - AT)
+
CO
2
K
K
net
1
0,39
40,00
0,51
53,00
0,51
54,00
0,65
63,00
0,69
65,00
0,76
70,00
0,45
48,00
0,46
48,00
0,00
0,00
0,53
53,00
0,49
51,00
x (O
- O
)
2base
2
O
2base
O + 9 x H) x (2488 + 2.1 x FT - 4.2 x AT)
2
Q
x 1000
gr
O + 9 x H) x (210 + 2.1 x FT - 4.2 x AT)
2
Q
x 1000
net
H
MH
O
Q
2
24,4
0
53,42
13
0
45,6
11,5
0,2
42,9
4
13
26,75
3
12
29,65
0,4
10
27,9
18,2
0
50
17,2
0
49,3
0
0
12,9
0
44,62
14,2
0
45,1
C0
:
Fuel-specific
2max
carbon dioxide value
O
O2 reference value
2base:
O
:
Measured oxygen
2
content as %
)
(
K1 x CO
+
CO
K1 x Q
)
(
+
Q
x (CO
net
Kgr/Knet/Qgr/Qnet/K1/MH2O/H:
Fuel-specific factors
FT:
Flue gas temperature
AT:
Ambient temperature
CO:
Measured carbon monoxide
value in %
CO
:
Calculated carbon dioxide
2
value in %
Q
gr
net
48,16
42,8
40,5
25,5
28,95
27,45
46,3
45,8
0
0
41,8
42,02
)
)
+ CO
2
x CO
)
)
gr
+ CO)
2

Advertisement