F. Configuration
This chapter describes the possible steps for adapting the product to the particular
measurement task or the requirements of the user.
Familiarity with the contents of the chapter Operation (see p. 15) is assumed
F.1 Instrument settings
F.1.1 Display edit
The parameters/units and the display representation (number of readings displayed per
display page) can be set.
Available parameters and units (may vary from one instrument to another):
Display
Parameter
FT
Flue gas temperature
AT
Ambient temperature
CO2
Carbon dioxide
O2
Oxygen
%
CO
Carbon monoxide
uCO
Carbon monoxide undiluted ppm
NO
Nitrogen monoxide
NOx
Nitrogen oxide
AT
Ambient temperature
Drght
Flue draught
SO2
Sulfur dioxide
NO2
Nitrogen dioxide
Itemp
Instrument temperature
DP
Flue gas dew point temp.
Effn
Effency referred to net
calorific value
Effg
Effency referred to gross
calorific value
ratio
Poison index
ExAir
Air ratio
Units
Display
°C, °F
Air
ΔP2
°C, °F
%
Gasfl
GasP
ppm, %, g / GJ,
3
mg/m
, mg/kW
OilFl
Oil p
ppm, %, g / GJ,
OilP
mg/m
3
, mg/kW
Pabs
ppm, %, g / GJ,
mg/m
3
, mg/kW
°C, °F
Pump
mbar, hPa, mmWS,
ΔP1
inW, Pa, psi, inHG
ppm, %, g / GJ,
mg/m
3
, mg/kW
Speed
ppm, %, g / GJ,
Flow
mg/m
3
, mg/kW
°C, °F
°C, °F
MCO,
%
MNOx,
MSO2
%
H2
-
%
Parameter
Air ratio
Differential pressure
(200hPa)
Gas flow rate
Gas burner output
Oil flow rate
Oil pressure
Oil burner output
Absolute pressure
Pump output
Differential pressure (40hPa) mbar, hPa, Pa,
Flow speed
Airflow
Mass flow
Hydrogen
27
.
Units
%
mbar, hPa, Pa,
mmWS, inW, psi,
inHG
m
3
/h, l / min
kW
kg/h
bar
kW
hPa , mbar, Pa,
mmWS, inW, psi,
inHG
l / min
mmWS, inW, psi,
inHG
m/s, fpm
3
3
3
m
/s, m
/m, m
/h,
3
3
3
m
/d, m
/y, f
/s,
f
3
/m, f
3
/h, f
3
/d,
f
3
/y, l/min
kg/h, kg/d, t/d, t/y,
lb/h
ppm